top of page

CSI Original Equipment Manufactured Products

CSI has been designing, testing, manufacturing, and implementing OEM products for over forty years.  Products that CSI designs and manufactures include Controllers, SCADA RTU's, Motor Monitors, UPS's, and the Hydrowatch.  Please see below for more details or reach out to us at 601-355-8594.

QC101_PHOTO.jpg

pump Controllers

SC101E Simplex Controller Features

  • Manual-Off-Automatic Selector Switch

  • Running, Failure, and Seal Failure Pilot Lights

  • High Level Input and LED Pilot Light

  • Flashing Common Alarm Light Output

  • Pump Failure and Seal Failure Delays

  • Common Alarm Relay Output

  • Power On and Pump Start Delays

  • Short-Cycle Delay

  • Optional Repeat Cycle Timer

  • Optional 7-Day Timer

  • Lamp Test Input

  • UL Recognized for use in Industrial Control Panels

DC101F Duplex Pump Controller Features

DC101F-L_small (1).jpg
  • Manual-Off-Automatic Selector Switch

  • Running, Failure, and Seal Failure Pilot Lights

  • High Level Input and LED Pilot Light

  • Flashing Common Alarm Light Output

  • Pump Failure and Seal Failure Delays

  • Common Alarm Relay Output

  • Power On and Pump Start Delays

  • Short-Cycle Delay

  • Optional Repeat Cycle Timer

  • Optional 7-Day Timer

  • Lamp Test Input

  • UL Recognized for use in Industrial Control Panels

DC201F Duplex Pump Controller Features

DC101F-L_small (1).jpg
  • Includes all features from the DC101F

  • Lift Station Analyzer 

  • RTU communication to CTU

  • Calculates Station Flow with SPLT

  • Includes Two Serial Ports (RS232 & RS485)

  • Over 100 data points available to SCADA including:

  • Four Analog Inputs - Wetwell Level, Two Motor Currents, and a Spare

  • Selector Switch Position

  • All Alarm Statuses

  • Pump Running Signals

  • Wetwell Level

QC101B Quadraplex Pump Controller Features

QC101_PHOTO.jpg
  • Quadraplex or Triplex Operation

  • Manual-Off-Auto Selector Switches

  • Start and Stop Levels for each pump

  • FIFO or LIFO operation

  • Pump Staggering for start and stop levels

  • Automatic Pump Alternation

  • Alternation on Pump Failure and Seal Failure

  • Running, Failure, and Seal Failure LED Pilot Lights

  • Maximum Run Timer Alternation

  • Flashing Common Alarm Light Output

  • Common Alarm Relay Output

  • Improper Sequence Alarm and Reset Pushbuttons

  • Alarm Telemetry Module Available Add-on

  • UL Recognized for use in Industrial Control Panels

level meter Controllers

MPCT6C_FRONT_small.jpg

MPCT6C Multipoint Current Trip Controller Features:

  • Six point Level Controller

  • Four Digit LCD Level Display

  • Isolated 4-20mA Level Signal Input and Output

  • Six Control Points with LED status indicators

  • Setpoints energized on Rising or Falling level

  • All settings available on display

  • Temperature Mode available

  • Signal Failure relay output with LED indicator

  • Auxiliary alarm relay output

  • Six SPDT dry contact relay outputs

  • Settings modifiable from display

  • Output Test Mode

  • Lamp Test Input

  • UL recognized for use in Industrial Control Panels

MPCT12C Multipoint Current Trip Controller Features:

MPCT12C_FRONT_small.jpg
  • Twelve point Level Controller

  • Four Digit LCD Level Display

  • Isolated 4-20mA Level Signal Input and Output

  • Twelve Control Points with LED status indicators

  • Setpoints energized on Rising or Falling level

  • All settings available on display

  • Temperature Mode available

  • Signal Failure relay output with LED indicator

  • Auxiliary alarm relay output

  • Twelve SPDT dry contact relay outputs

  • Settings modifiable from display

  • Output Test Mode

  • Lamp Test Input

  • UL recognized for use in Industrial Control Panels

process Controllers

FDC101A_COLOR_small.jpg

FDC101 Frequency Drive Controller Features:

  • VFD speed pacing based on level and number of pumps running

  • 3.5 Digit LCD Display with adjustable range control

  • Isolated 4-20mA analog input

  • LED setting status indicators

  • Four pump running digital inputs

  • Minimum and Maximum level settings for each stage

  • Pump Up and Pump Down operation

  • Settings viewable on display

  • Two or Four Isolated 4-20mA Outputs

  • Pushbutton Settings

  • RS485 Modbus Communication

  • Lamp Test Input

  • UL recognized for use in Industrial Control Panels

RDB_1850.jpg

CFC101 Chemical Feed Controller Features:

  • 3.5 Digit LCD Display with adjustable range control

  • Six Individual Flow Settings

  • Dry Contact Running Inputs

  • Individual and Total Flowrates visible on display

  • Two Relay Outputs - (1) Constant and (1) Proportional 4-20mA Output

  • Optional 4-20mA Chart Recorder Output for each Flowrate

  • Lamp Test Input

  • UL recognized for use in Industrial Control Panels

motor monitors

MM101 Motor Monitor Features:

MM101A.jpg
  • One 5-amp current transformer input

  • True RMS Amperage reading on a 3.5 Digit LCD Display

  • Six Digit resettable LCD elapsed time meter

  • Tri-Colored LED status indicators

  • Running and High Amp settings with variable On/Off delays

  • Two Relay Outputs

  • Optional Isolated 4-20mA Outputs

  • UL recognized for use in Industrial Control Panels

CT420 Dual CT to 4-20mA Output Converter Features:

CT420A-1_111404_small.jpg
  • Dual 5-amp CT inputs

  • True RMS conversion

  • Two Isolated Outputs (4-20mA)

  • Power On Status LED

  • Quick Disconnect Terminals

  • Snaptrack or Backplate mounting

hydrowatch

RS4_8830.jpg

The HydroWatch is designed to prevent water-logging or air-logging of the hydropneumatic tank under normal operating conditions.  Water and air connections are made from the back of the HydroWatch panel to the tank, usually where the sight glass is located.  The sight glass is now located inside the panel, visible through a viewing window, and completely protected from freezing weather.  Probes are located inside the enclosure in a tube that is a physical extension of the tank.  This tube is isolated with shut-off valves in the water and air lines, which facilitates servicing the system.  Conducting service on the system no longer requires de-pressurizing the tank which causes customers to experience reduced pressure for several days waiting for the system to re-balance.    The tube in the panel is de-pressurized for servicing and the customers don't experience any loss of pressure.
​

NEMA 4X ENCLOSURE

​

The Hydro Watch panel provides all of the controls required for your hydropneumatic tank systems within one factory built unit, housed in a NEMA 4X fiberglass enclosure. All sensors and control components are prewired. Level and pressure sensors are adjusted specifically for your system. The entire unit is then completely tested for proper operation prior to shipment.

FIELD ADJUSTABLE

​

Tank pressure is viewable on a pressure gauge and tank level is viewable from a level sight gauge, complete with anti-freezing thermostat and heater. Manual/Off/Auto switches are provided for pumps and air compressor. A Reservoir Low Level stop is provided for pumps. For flexibility, the system is field convertible from simplex to duplex operation.

RS4_8831.jpg
RS4_8842.jpg

SELF BALANCING SYSTEM

​

The panel provides automatic pressure and level controls in a unique Self Balancing system. If the system water/air ratio becomes unbalanced due to power failure or other interruption of normal conditions, the Hydro Watch will automatically regulate to the preset values. The system includes automatic pressure control to start the pump(s) controlling liquid level in the tank. An automatic pressure sensor adjusts tank air pressure by adding air from an integral air compressor. Over pressure is controlled by the pressure sensor and electric solenoid.  An electronic controller is provided to allow easy adjustment of pressure control points. The tank pressure and setpoints are viewable on an integral LCD (Liquid Crystal) display. Level control is achieved without probes in the tank. Automatic level controls start pumps at predetermined tank low level, should air pressure build in the tank.

Address

909 Quinn Street

Jackson, MS 39202

Phone

601-355-8594

Email

CSI logo 2021 Temp_001.png
bottom of page