Controllers

CSI manufactures a complete line of products for all pump station applications. We manufacture over 50 Products

simplex

  • MANUAL-OFF-AUTO SELECTOR SWITCH
  • RUNNING AND FAILURE PILOT LIGHTS
  • SEAL FAILURE PILOT LIGHT
  • LEVEL INPUT PILOT LIGHTS
  • HIGH/LOW LEVEL ALARM PILOT LIGHT
  • COMMON ALARM LIGHT WITH DIM GLOW
  • COMMON ALARM DRY CONTACT OUTPUT
  • ADJUSTABLE MOTOR FAILURE DELAY
  • ADJUSTABLE POWER ON DELAY TIMER
  • ADJUSTABLE PUMP START DELAY
  • ADJUSTABLE SEAL FAILURE DELAY
  • ADJUSTABLE SHORT CYCLE DELAY
  • LAMP TEST
  • 120VAC POWER
  • INTEGRATED QUARTZ 7-DAY TIMER (Additional Feature)

duplex_controller

  • MAN-OFF-AUTO SELECTOR
  • SWITCHES
  • MOTOR LEAD / LAG
  • SELECTOR SWITCH
  • PILOT LIGHTS FOR RUNNING,
  • FAILURE, SEAL FAILURE,
  • HIGH/LOW LEVEL AND AUXILIARY ALARM
  • PILOT LIGHTS FOR EACH LEVEL INPUT
  • COMMON ALARM LIGHT WITH DIM GLOW
  • COMMON ALARM DRY CONTACT OUTPUT
  • AUTOMATIC MOTOR ALTERNATION
  • 14VDC OPTICALLY ISOLATED INPUTS WITH MAX CURRENT OF 12madc.
  • LAG MOTOR START IF LEAD FAILS
  • ADJUSTABLE MOTOR FAILURE DELAYS
  • ADJUSTABLE POWER-ON DELAYS
  • ADJUSTABLE PUMP OFF-DELAYS
  • ALARM TELEMETRY OUTPUTS ARE OPTICALLY ISOLATED, OPEN-COLLECTOR
  • TRANSISTOR TYPE
  • FLOAT TEST / IMPROPER SEQUENCE ALARM OPTION
  • LAMP TEST INPUT
  • REPEAT-CYCLE TIMER OPTION BOARD
  • 7-DAY PROGRAMMABLE TIMER (Additional Feature)
  • SWITCH POSITION OUTPUT OPTION
  • SERIAL PORT (RS232) OUTPUT OPTION
  • UL RECOGNIZED FOR USE IN INDUSTRIAL CONTROL PANELS
  • 120 VAC POWER SUPPLY

DC201B

  • MAN-OFF-AUTO Selector Switches
  • Pilot Lights for Running, Failure, Seal Failure, High/Low level, and Auxiliary alarm
  • 12v dc Optically Isolated Inputs With Max Current of 15ma dc
  • LAG Motor Start if Lead Fails
  • Adjustable Motor Failure Delay and Seal Failure Delay
  • 1-Wire Communications Option
  • Eight Open-Collector Transistor Digital Auxiliary Outputs
  • Two RS232 Serial Ports
  • RTU Addresses Supported:000-999
  • User Selectable Baud rates of 4800 OR 9600
  • LSA 2000 Operation
  • Duplex Pump Controller With Telemetry(DC201B)
  • 120VAC or 12VDC power supply

quadraplex_controller

  • MANUAL-OFF-AUTO Selector Switches
  • Front Panel level Input Pilot Lights
  • Motor Running and Failure Lights
  • Seal Failure Pilot Lights
  • Improper Sequence Pilot Light
  • High/Low Level Alarm Pilot Light
  • Common Alarm Light With Dim Glow
  • Common Alarm Dry Contact Output
  • Separate Start and Stop Levels for Each Motor
  • 24v dc level and Moisture Sensing Circuits With Intrinsic Safety
  • Master Controller Inputs
  • Adjustable Motor Failure Delay
  • Adjustable Power on Delay Timer
  • Quadraplex or Triplex Operation
  • Lamp Test Feature

6_point_control

  • 3 1/2 Digit LED or LCD Readout
  • Display Range Adjustable from The Front of the Unit
  • Offset Zero Feature
  • Differential Input Impedance
  • 250 OHM Input Impedance
  • Transducer or 4-20ma dc Inputs
  • Six individual Control Points
  • Lamp Test Option
  • Panel Mounted
  • 4-20ma or 1-5v dc Output
  • 120 VAC @ 60 HZ Power

12point_control

  • 3 1/2 Digit LED or LCD Readout
  • Display can be Calibrated from the Front of the Unit
  • Display Zero can be Off Set
  • Transduser or 4-20ma dc Inputs
  • Twelve Individual Control Points
  • Set points are Visible On Display
  • Lamp Test Option
  • Panel Mounted
  • 4-20ma or 1-5v dc Output
  • 120VAC @ 60 HZ Power

DCF 1.0

  • 3 ½ DIGIT LED OR LCD DISPLAY
  • SIX INDIVIDUAL FLOW SETTINGS
  • DRY CONTACT RUNNING INPUTS
  • INDIVIDUAL AND TOTAL FLOWRATES ARE VISIBLE ON THE DISPLAY
  • FLOWRATES ADJUSTABLE FROM FRONT
  • TWO RELAY OUTPUTS — ONE CONSTANT AND ONE PROPORTIONAL
  • ONE PROPORTIONAL 4-20ma OUTPUT
  • OPTIONAL 4-20ma CHART RECORDER
  • OUTPUTS FOR EACH FLOWRATE
  • LAMP TEST FEATURE
  • 115/120 VAC @ 60 HZ POWER
  • PANEL MOUNTED UNIT
  • NAMEPLATE DIMENSIONS: 6 3/4″ WIDE X 8″ HIGH

  • 3 ½ DIGIT LED OR LCD DISPLAYS (FOR LEVEL INPUT AND PERCENT OUTPUT)
  • MIN. AND MAX. LEVEL SETPOINTS FOR EACH OF THE FOUR RANGES.
  • INPUT STATUS LED’S ON BACK OF BOARD
  • PUMP RUNNING PILOT LIGHTS
  • OPTICALLY ISOLATED RUNNING INPUTS
  • 4-20 MADC LEVEL INPUT
  • FOUR ISOLATED 4-20 MADC OUTPUTS
  • ALL SETPOINTS ARE VIEWABLE ON
    DISPLAY AT ANY TIME
  • SETPOINTS ADJUSTABLE FROM FRONT
  • LAMP TEST FEATURE
  • 115/120 VAC @ 60 HZ POWER
  • PANEL MOUNTED UNIT
  • NAMEPLATE DIMENSIONS: 6 3/4″ WIDE X 8″ HIGH